Flo-Gage™ 7000 / 8000 Series
Option OC — Cleaned for Oxygen Service per ASTM G93-96
Safety Notice: Oxygen under pressure can react violently with hydrocarbons and contaminants. Standard meters are not suitable for oxygen service. Option OC provides ASTM G93-96 cleaning, inspection, and sealed packaging required for safe oxygen service.
The RCM Flo-Gage™ Oxygen Flow Meter is the standard 7000/8000 Series gas meter prepared specifically for oxygen service. Each unit is cleaned in accordance with ASTM G93-96, inspected per section 11.4.1.2, then packaged and bagged in polyethylene bags per section 12.1.3 to maintain cleanliness until installation.
Because oxygen meters are individually sized, Option I (Compressed Gas Service) is also required — the gas measured, operating temperature, and pressure at the meter inlet must be provided at time of order. The meter is then calibrated specifically for your oxygen system conditions.
Must be ordered with Option I — specification of gas measured, temperature, and pressure at meter inlet is required.
| Component | Standard | Options |
|---|---|---|
| Housing | Polycarbonate | Aluminum |
| Body | Bronze | Monel / 316 SS |
| Bellows | Bronze | Monel / 316 SS / Inconel |
| Seals | Viton | Teflon / EPR |
| Crystal | Polycarbonate | Glass |
| Gear Movement | Bronze | 316 SS |
| Specification | Standard | Optional |
|---|---|---|
| Accuracy | ±3% F.S. | — |
| Repeatability | ±1% F.S. | — |
| Maximum Pressure | 180 psig | 400 psig |
| Minimum Pressure | 10 psig | 10 psig |
| Maximum Temperature | 212°F (100°C) | 350°F (177°C) |
| Minimum Temperature | -30°F (-34°C) | -80°F (-62°C) |
Example Model Number
| Code | Description |
|---|---|
| L | Right to Left |
| R | Left to Right |
| VUR | Vertical Up Flow, Dial Right |
| VUL | Vertical Up Flow, Dial Left |
| VDR | Vertical Down Flow, Dial Right |
| VDL | Vertical Down Flow, Dial Left |
7000: ¼″–3″ threaded · 8000: ½″–8″ wafer
| Code | Description |
|---|---|
| B2 | Teflon Seals |
| E | Non-Standard Flow Rate |
| ES | Low Flow Rate (½″ 7000 Series only) |
| F | Aluminum Housing with Plastic Dial Crystal |
| F2 | Aluminum Housing with Glass Dial Crystal |
| G | Custom Scales and Dials |
| I | Compressed Gas Service — required for oxygen; gas, temperature & pressure at inlet must be specified |
| OC | Cleaning for Oxygen Service — ASTM G93-96; inspected per 11.4.1.2; packaged in polyethylene bags per 12.1.3 |
| P | Panel Mount (1½″ and smaller only) |
| R3 | Remote Readout, 316 SS (Mechanical Indicator) |
| Nominal Size | Series 7000 (Threaded) | Series 8000 (Wafer) |
|---|---|---|
| ¼″ | 5.95″ (151mm) | n/a |
| ½″ | 5.95″ (151mm) | 6.62″ (168mm) |
| ¾″ | 5.95″ (151mm) | 7.06″ (179mm) |
| 1″ | 6.07″ (154mm) | 7.25″ (184mm) |
| 1½″ | 6.39″ (162mm) | 7.81″ (198mm) |
| 2″ | 6.80″ (172mm) | 8.00″ (203mm) |
| 2½″ | n/a | 8.54″ (217mm) |
| 3″ | 7.48″ (190mm) | 8.87″ (225mm) |
| 4″ | n/a | 9.95″ (252mm) |
| 5″ | n/a | 10.36″ (263mm) |
| 6″ | n/a | 11.05″ (280mm) |
| 8″ | n/a | 12.30″ (311mm) |
Dimensions based on bronze meters.
Common questions about safety requirements, ASTM G93-96 cleaning, and specifying RCM Flo-Gage meters for oxygen service.
Have an oxygen service application question not covered here?
Our engineering team is available Mon–Fri, 8:30am–4:30pm EST.
Flo-Gage™